© GDC Group Ltd. 20125122722/06Model 940Inset live fuel effect gas fireIncorporating the VALOR CONTROLFitted with one of the following fascia.Adorn, D
b) All relevant national and local rules in force.Where no specific instructions are given, reference should be made to the relevantBritish Standard C
3.6.2 Any chimney damper or restrictor should be removed. If removal is not possible,they must be secured in the open position.3.7 Fireplace preparati
3.9 Fireplace clearances.3.9.1 Adorn model onlyThe minimum height from the base of the fireplace opening to the underside of any shelfmade from wood o
© GDC Group Ltd. 2012Page 133.9.2 The minimum allowable distance from the outside of the appliance fascia to acorner wall having combustible material
© GDC Group Ltd. 2012Page 143.10 Installation options.In the United Kingdom, as supplied, the appliance can be installed in the followingsituations: -
3.10.1.1 ‘Hole-in-the-wall’ Installations- It is recommended that a hearth should be installed as in section 3.8.- Icon firefront If when using the Ic
3.10.2 Metal flue box and hearth.The appliance can be installed toa fireplace incorporating a metalflue box complying with theconstructional requireme
- 175mm diameter flue pipe. SeeBS6461 Part 1 for suitablematerials.- Single wall, twin wall or flexibleflue liner with a minimum diameterof 125mm. The
Carefully remove all the contents. Take special care in handling the ceramic pieces.Take care not to bend or distort the slide control linkage when ha
© GDC Group Ltd. 2012Page 19INSTALLER GUIDEFigure 9. Pack contents
© GDC Group Ltd. 2012All rights reserved. No part of this publication may be reproduced in any material form(including photocopying), stored in any me
© GDC Group Ltd. 2012Page 20Section 2 - Visage fascia pack contains:1 Fascia with sliding control.1 Fire front casting. 1 Outlet baffle.1 Burner tray
5.1 Soundness for appliance attachment.Two primary methods of retaining the appliance are provided: -1) By fixing to the fireplace front surround.2)
5.2 Fireplace flue pull.Close all doors and windows in the room in which the appliance is to be installed.After confirming with a match that smoke is
Concealed Supply Pipe Connection.If a concealed connection from inside the fireplace is required then, before theappliance is fitted into the fireplac
6. The Adorn, Visage, Masquerade,Excelsior and Dream models have anoutlet baffle supplied with the appliancefascia. Fit this to the convected air outl
9. There is a length of self adhesive foam sealsupplied with the fire. This will need to be fitted tothe outer rear edges of the side and top flangeso
9.1 Method 1 - Front fixing to fireplace surround.1. Make sure that the fireplace front surroundarea is sound enough to take the fibre / woodenplugs a
should be drilled within the range of positions shown in figure 21 using a suitablysized masonry drill bit for the wall plugs supplied. The holes shou
10. Fit a cable retainer over the bottom end of each cable.11. Pull each cable taut. Push the cable retainers hard up against the back panel. Theend o
10.1 Burner and supply pipe installation.1. Refit the burner unit to the convection box with two screws.2. Connect the supply line to the appliance.3.
Safety First.Valor fires are CE Approved and designed to meet the appropriate British Standardsand Safety Marks.Quality and Excellence.All Valor fires
10.3 Inlet pressure check.The appliance is pre-set to give the correct heat input at the inlet pressure shown insection 2 of this manual. No adjustmen
2. Remove four screwsfrom the spillage plate sides(See figure 30). 3. Remove the spillageplate by lifting it forward.4. Fit the ceramic side wallsagai
3. Place the fascia against the fireplace frontsurface so that the two retaining plates at theback of the fascia are above the two upperretaining brac
12.2 Adorn, Icon and Visage fasciasCarefully lift the fascia. Do not lift it by the slider control knob.Remove the tape securing the control linking b
Swing the bottom control linking bar towards thecentre of the fire to clear the front casting. Slide thefront casting sideways, if necessary, to align
The installer and owner guide for the ceramic fuel effect is supplied with the ceramicfuel effect. It is important that the fitting guide for the cera
14.3 Icon front cover.Locate the top flanges ofthe bottom front coverbehind the bottom edgeof the fascia. Fix thesides of the cover to thefascia botto
4. Gradually slide the control knob up to increase the burner setting. The burnershould be at its maximum setting at the high heat position shown in f
15.3 Flame supervision and spillage monitoring system.This pilot unit includes a system that will automatically shut off the gas supply if thepilot fl
1. COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICESECTION OF THE OWNER GUIDE (See last pages of the OWNER guide).2. If a gap is visible between t
© GDC Group Ltd. 2012Page 4INSTALLER GUIDEFOR OWNER GUIDE SEE PAGES 48 TO 60INSTALLER GUIDE
- Always turn off the gas supply and allow the fire to cool completely beforecommencing any servicing (The appliance inlet ‘T’ connector incorporates
17.1 Checking the aeration setting of the burner.1. The aeration shutter is factory set and shouldnot require adjustment. If the shutter is not asshow
17.4 To remove the fascia.1. Remove the bottom front cover / fire front casting.2. Detach the control-linking bar from the control pivotbracket by rem
Dream, Masquerade, Excelsior, Classica model.The control slide unit is secured to the convection boxand not the fascia.1. Remove the fascia (See secti
17.7 To remove the complete burner unit.1. Remove the bottom front, fire frontcastings and the fascia (See section17.4).2. Remove the ceramic fuel eff
5. Refit in the reverse order. If the microswitch leads cannot be easily attached to theinterrupter block when it is fully tightened to the gas shut-o
8. If fitting a new tap, remove the hexagonal nut at the mounting bracket end of theold tap and fit to the replacement tap. Refit in the reverse order
17.13 To replace the burner. (See figure 59).1. Remove the burner unit (See section 17.7).2. Support the elbow injector and unscrew theinjector nut.3.
© GDC Group Ltd. 2012Page 48OWNER GUIDEFOR WARRANTY AND SERVICE INFORMATIONSEE PAGES 57 TO 60OWNER GUIDE
Section PageSAFETY 50APPLIANCE DIMENSIONS AND CLEARANCES 52GAS CONSUMPTION 53OPERATING YOUR FIRE 53The Oxysafe flame sensing and flue blockage saf
Section PageINSTALLER GUIDE 4 - 47OWNER GUIDE 48 - 601. SAFETY AND UNPACKING 72. APPLIANCE DATA AND EFFICIENCY 82.1 General information. 82.2 Effi
Do have the fire installed by a competent person. In the United Kingdom, installationmust be in accordance with the latest edition of the Gas Safety (
© GDC Group Ltd. 2012Page 51OWNER GUIDEVISAGE, DREAM, Masquerade, Excelsior, Classica AND ICON MODELS ONLYFigure 2. Combustible shelf clearances for V
© GDC Group Ltd. 2012Page 52OWNER GUIDEKey DescriptionModelDream,Masquerade,ExcelsiorAdorn Visage Icon ClassicaA Height (mm)636 768 636 622 631B Width
Model 940Has a maximum natural gas input of 6.85kW (Gross)Has a maximum natural gas output of 4.0kW Has a minimum natural gas input of 2.7kW (Gross)Ha
Until you can obtain a replacement battery the fire can be lit with a taper as describedlater in this guide.2. Keep the control knob at the ignition p
To maintain the high performance and quality finish of your fire please follow theseguidelines:Before attempting to clean the fire, please remember to
The installer and owner guide for the ceramic fuel effect is separate from this guide.The installer may have attached it to this guide or placed it in
Regular maintenance.In order to achieve and maintain high levels of personal safety and performanceefficiency, it is essential that the opening at the
What you need to do if you experience a problem with the operation of the fire: - You should always contact your installer first, because the cause of
© GDC Group Ltd. 2012Page 59OWNER GUIDETo be completed by Installer:Installer Details (Block Capitals)Installer NameGas Safe Register Number.Company N
Section Page10. BURNER AND SUPPLY PIPE INSTALLATION 2910.1 Burner and supply pipe installation. 2910.2 Preliminary burner checks. 2910.3 Inlet pres
© GDC Group Ltd. 2012Page 60OWNER GUIDEA LABEL CONTAINING THE SERIAL NUMBER MAY HAVE BEEN PLACED INSIDE THIS BOX.SERIAL NUMBER LABELTO BE AFFIXED HERE
Before continuing any further with the installation of this appliance please read thefollowing guide to manual handling.- The lifting weight (kg) of t
2.1 General information.*When converted using kit 0595211.The appliance information label is located on a plate at the base of the fire. This canbe se
3.1 Regulations, Standards and Law.The installation must be in accordance with these instructions.For the user’s protection, in the United Kingdom it